Drayton 3 Port Mid Position Valve Wiring Diagram



If you're looking for a diagram to help you install a Drayton 3 Port Mid Position Valve, you've come to the right place. This valve is used in many heating systems around the world, and it's important to understand the wiring process to ensure a successful installation.

In this blog post, we'll walk you through the wiring process step-by-step. We'll also cover some key safety tips to keep in mind as you work. By the end of this article, you'll know the wiring basics and be ready to start your project.

Before you get started, it's important to understand the components involved. The Drayton 3 Port Mid Position Valve has two ports: an input port (where power enters the system) and an output port (where energy is sent out). It also has a built-in power resistor, which helps regulate the flow of energy.

The first step is to connect the input and output ports to the appropriate wires. For the input port, connect the red wire to the "L" terminal and the blue wire to the "N" terminal. For the output port, connect the black wire to the "C" terminal and the white wire to the "E" terminal.

Next, connect the power resistor to the "P" terminal. Use the provided screws to secure the resistor in place.

Now that everything is connected, it's time to turn on the power. Make sure that the power switch is in the "on" position before you do anything else.

Once the power is on, you can check the wiring with a voltmeter. First, take a reading from the red and blue wires at the input port. They should both have the same voltage, which should match the voltage of the incoming power. Then take a reading from the black and white wires at the output port. They should have the same voltage, but it should be lower than the input voltage. If these readings don't match up, there may be a wiring issue and you'll need to double-check your connections.

Finally, make sure that the power resistor is working properly. Take a reading from the "P" terminal and make sure it matches the voltage of the incoming power.

Now that you've successfully wired the Drayton 3 Port Mid Position Valve, all that's left is to test it. Turn off the power, open the valve, and then turn the power back on. If the valve opens successfully, you've completed the wiring process and are ready to start using your system.

We hope this guide has helped you understand the wiring process for the Drayton 3 Port Mid Position Valve. Always remember to follow safety protocols when working with electricity, and if you ever have any doubts about wiring, it's best to have a professional handle the job. Good luck!


Drayton 27651sx 3 Port Mid Position Valve Actuator Motorised Valves Fix Com

Drayton 27651sx 3 Port Mid Position Valve Actuator Motorised Valves Fix Com


Installation Instructions Mid Position Valve Val322mp Val328mp Specifications Manualzz

Installation Instructions Mid Position Valve Val322mp Val328mp Specifications Manualzz


Honeywell Motorised Valves Problems And Fault Finding

Honeywell Motorised Valves Problems And Fault Finding


Corgi 3 Port Mid Position Motorised Valve 22mm Toolstation

Corgi 3 Port Mid Position Motorised Valve 22mm Toolstation


Drayton Specifications Ing Removing Actuator Manualzz

Drayton Specifications Ing Removing Actuator Manualzz


Installation And Wiring Guide

Installation And Wiring Guide


Installer Handbook

Installer Handbook


Wiring Diagram Plumbersforums Net

Wiring Diagram Plumbersforums Net


Heating System Wiring Only Works With Hw On Diynot Forums

Heating System Wiring Only Works With Hw On Diynot Forums


Are My 2 Port Valve Wired Incorrectly Kettling Problem Diynot Forums

Are My 2 Port Valve Wired Incorrectly Kettling Problem Diynot Forums


W Plan Central Heating System

W Plan Central Heating System


How A Y Plan Heating System Works Design Boiler Boffin

How A Y Plan Heating System Works Design Boiler Boffin


S Plan Central Heating System

S Plan Central Heating System


Very Unusual Problem With Drayton Ma1 Plumbersforums Net

Very Unusual Problem With Drayton Ma1 Plumbersforums Net


Drayton Product Catalogue 2009

Drayton Product Catalogue 2009


Vaillant Ecotec 831 Combi On 2 Zone Heating System Plumbersforums Net

Vaillant Ecotec 831 Combi On 2 Zone Heating System Plumbersforums Net


Drayton 27206sx 3 Port Motorised Valve 28mm Compression Valves Fix Com

Drayton 27206sx 3 Port Motorised Valve 28mm Compression Valves Fix Com